XY-T01 Digital Temperature Control LED Thermostat

R 180.00

The XY-T01 Digital Temperature Control LED Thermostat has a heating mode ("H") and a cooling mode ("C"), with the function of a high temperature alarm ("ALA"), delayed start ("OPH"), temperature correction function -10.0~10.0°C ("OFE" ), remote parameter reading/setting and real-time temperature report. The electronic thermostat can be used in a variety of equipment.

Quantity

Stock Available
92 Items

Overview:

The XY-T01 Digital Temperature Control LED Thermostat has a heating mode ("H") and a cooling mode ("C"), with the function of a high temperature alarm ("ALA"), delayed start ("OPH"), temperature correction function -10.0~10.0°C ("OFE" ), remote parameter reading/setting and real-time temperature report. The electronic thermostat can be used in a variety of equipment.

Features:

• Heating Mode: When the detected temperature is less than or equal to the set temperature minus the return difference temperature, the relay is turned on and the heating device starts to work. When the detected temperature is greater than the set temperature, the relay is turned off and the heating device stops working;
• Cooling mode: When the detected temperature is greater than or equal to the set temperature plus the return difference temperature, the relay is turned on and the heating device starts to work. When the detected temperature is less than the set temperature, the relay is turned off and the heating device stops working.
• Waterproof probe: XY-T01 electronic thermostat is equipped with a 0.5-meter NTC10K probe, which is made of stainless steel, is waterproof and rust resistant, easy to use and can last for a long time.
• Reliable and durable: The performance of the electronic temperature control switch module is stable, and the control accuracy is 0.1 degrees Celsius.

Specification:

• Product model: XY-T01
• Power supply: DC6.0-30v or 5v micro USB
• Temperature control range: -50℃-110℃
• Temperature control accuracy: 0.1℃
• Measuring input: NTC10K/B3950
• Refresh rate: 0.5 seconds
• Output type: relay output 10A
• Probe type: waterproof NTC probe
• Probe's length: 0.5 m
• High temperature alarm ALA: sound-light alarm
• Delay start OPH: 0-9999 minutes
• Temperature correction: -10 to 10℃, actual temperature = measuring temperature + calibration value
• Size: 68 x 42 x 15 mm

Instructions:

Working mode/setting temperature/return temperature setting:
1. In the running interface, short press the "set" key to enter the quick setting interface;
2. After entering the quick setting interface, short press the "set" key to switch the parameters you want to set (work mode/set temperature/return temperature);
3. Use the "up" "down" key to modify the parameter value, and they support short press/long press;
4. Press and hold the "set" button for more than 3 seconds or without any button operation for 6 seconds , it will save the parameters and automatically exit the quick setting interface.

Set ALA/OPH/OFE (alarm temperature /delay starting setting/temperature correction):
1. In the running interface, long press "set" for more than 3 seconds to enter the parameter setting interface;
Set Temperature ---- SetT;
Backlash Temperature --- BackT;

1.Heating Mode:
When Temperature ≤ SetT- BackT; Relay conduction, heating equipment begin to work;
WhenTemperature ≥ SetT, Relaydisconnect, heating equipment stop work;

2.Refrigeration mode:
When Temperature ≥ SetT+ BackT;Relay conduction, refrigeration equipment begin to work;
When Temperature ≤ SetT;Relay conduction, refrigeration equipment stopwork;

3.High Temperature Alarm:
When Temperature ≥ AlarmTemperature,The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;

4.Delay Start:
When a normal heating or refrigeration work is done, the system starts to time T, and only after the T≥OPH, the system can carry out the next round of heating or refrigeration work;

5.Temperature Correction Function (-10.0 ~ 10.0°):
The system will work for a long time and may have deviations that can be corrected by this function,Temperature= Measured+ Calibration;

6.Parameter Remote Read/Set:
The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.

7.Real-time Temperature Report:
If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection.

8.Relay enable (default enable):
If the relay is disabled, the relay remains disconnected

9.Restore factory Settings:
At the same time press the STOP, set key more than 3S, restore factory settings

Working mode setting /backlash temperature :
• In the running interface, short press the "set" key to enter the quick setting interface;
• After entering the quick setting interface, short press the "set" key to switch the parameters you want to set (work mode/set temperature/return temperature);
• Use the "up" "down" key to modify the parameter value, and they support short press/long press;
• Press and hold the "set" button for more than 3 seconds or without any button operation for 6 seconds , it will save the parameters and automatically exit the quick setting interface.

Alarm temperature/delay Start /temperature correction:
1. In the operating interface, long press SET more than 3s, enter the parameters to set the interface;
2. Enter the parameter to set the interface, through the short press SET key to switch to set the parameters ;
3. through the UP DOWN key, modify the parameter value, support short press/long press;
4. Long press SET 3s above or continuous 6S without any key operation, exit parameter set interface, and save parameters;

How to turn on high temperature alarm (default off):
Enter the parameter setting interface, switch to the alarm parameter ALA , turn on or off the high temperature alarm function by short pressing the STOP button, and if the high temperature alarm function closes, ALA displays ‘—-‘ as a reminder;

How to turn on delay start (default off):
Enter parameter setting interface, switch to alarm parameter OPH, turn on or off high temperature alarm function by short Press STOP button, if high temperature alarm function closes, OPH show ‘—-‘ to remind;

Package includes:

• 1 x XY-T01 Digital Temperature Control LED Thermostat

AC Mode

DC Mode

552
92 Items

Specific References